Page 11 of 18
Drawing : - TPC262
Issue : - 8
Date : - 10/12/13
TROUBLESHOOTING
YMPTOM
C
AUSE
R
EMEDY
Unit inoperative
(no red light)
1. No power to unit
1. Check the power supply
and fuse
Little or no airflow
1. Loose fan on shaft
2. Fan motor burnt out
3. Dirty refrigeration coils
4. Loose electrical wiring
1. Tighten fan
2. Replace the fan motor
3. See Routine Maintenance
Section
4. Check the wiring diagram
to find fault and repair
Little or no water
extraction
1. Insufficient air movement
2. Compressor fault
3. Loss of refrigerant gas
4. Blocked filter dryer
1. Check all of the above
2. Contact the Factory
Service Center
3. Contact the Factory
Service Center
4. Contact the Factory
Service Center
Little or no defrost
when required
1. Faulty Timer
2. Faulty bypass timer
1. Contact the Factory
Service Center
2. Contact the Factory
Service Center
Unit vibrates
excessively
1. Loose compressor mounts
damaged
2. Damaged Fan
1. Tighten the nuts on the
compressor mounts
2. Remove obstruction
Spare parts available online